Sequence Of Operation - Cooler
Temperature Thermostat
All standard units are equipped with an adjustable thermostat located on the lower right hand side of the evaporator coil, on the
inside of the walk-in. All units are set at the factory to the temperature requested by the customer. Minor adjustments in
operating temperature may be made to suit your needs by a qualified refrigeration technician. Polar King recommends that you do not
set the temperature colder than required, as this will cause unnecessary power consumption. Recommended temperature for a cooler
ranges from +34° to +37° F, unless specified otherwise for special applications.
Refrigeration
These units are designed for application conditions 33°F and above. CAUTION: DO NOT SET A COOLER BELOW 32°F OR DAMAGE MAY
OCCUR.
Defrost
Defrost is accomplished during refrigeration off cycle. Four defrost cycles per day are programmed at the factory (4 a.m., 10 a.m.,
4 p.m., and 10:00 p.m.). It may be necessary to change the defrost cycle times to fit your work schedule.
The interior temperature may rise slightly during the defrost cycle. Do not be alarmed. Soon after the cycle is complete, the unit
will return to proper temperature.